MEDISPA.PRO
HMI.ADVA.30 HMI · International flagship high-tech modalities (Aesthetic medicine and body contouring department)

Room HMI.ADVA.30 · Device-based body remodelling and HIFEM room

Industry analytical passport of room type High-tech equipment unit. Full profile of architectural TEP, medical equipment specification (CapEx), MEP engineering loads (HVAC, electrical, water supply and drainage), resort price benchmarks and unit economics financial model.

Net usable area NUA
14.0 m²
GBA: ~18.2 m²
Treatment stations
1 station
Type: T4
Equipment CapEx
12 000 000 ₽
1 items
CapEx Finishes / MEP
2 310 000 ₽
Class V
Total investment
14 310 000 ₽
Turnkey incl. VAT
Payback period
— mo
Base scenario

🏛 1. Architectural and planning parameters and zoning

Total area: 14.0 m²

Building requirements and finishing materials (SanPiN)

Cleanliness class:Class V
Wet point:Required (cold + hot water + drain)
Ceiling height:≥ 3.0 m (clear height)
Door opening width:≥ 1.0–1.2 m (medical standard)
Floor covering:Homogeneous antistatic linoleum
Wall finish:Moisture-resistant paint / disinfectant resistance

Functional zone schedule (3 zones)

Functional zone Area Purpose and technological equipment
Specialist's consultation and work area 4.2 m² Physician/nursing workstation, documentation and MIS
Procedure and treatment zone 7.7 m² Procedure and device treatment zone for 1 station
Preparation and disinfection area 2.1 m² Storage of sterile consumables and disinfectants

⚡ 2. Engineering and technology profile (MEP)

Electrical 3.5 kW · HVAC +3.0/-3.0

Electrical (power supply)

Installed power:
3.5 kW
Design power (Kd=0.72):
2.52 kW
Cable lines:
2 beams
Distribution board:
230V / 50Hz (dedicated medical distribution board)
Residual current protection (RCD):
Individual medical type 'A' RCDs 10 mA / 30 mA
Medical UPS:
None kVA (None min)

HVAC (ventilation & SanPiN)

SanPiN cleanliness class:
Class V
Supply air exchange:
+3.0 ACH
Exhaust air exchange:
-3.0 ACH
Temperature:
20-22°C
Humidity:
45-55%
Gas destruction:
General ventilation filtration

Water supply & drainage and safety

Cold/hot water points:
1 stations (elbow-operated)
Floor drains:
1 pcs (dry trap)
Water treatment:
Standard cold water filtration
Clinical and technological rationale for synergy
Automatic fire alarm, type 2-3 warning and evacuation system, powder/gas fire extinguishers
Nurse call system:
Installed at stations

🔬 3. Medical and spa equipment specification (CapEx)

12 000 000 ₽
№ Equipment name Brand / Manufacturer Country Ministry of Health registration certificate Qty Unit price Amount (CapEx)
1 BTL Emface Synchronized RF & HIFES Facial Toning System

A breakthrough method applying radiofrequency (RF) energy and high-intensity electrical stimulation (HIFES) at once to the facial muscles (zygomatic and frontal) for non-surgical lifting and elastin synthesis.

★ HERO HIGH-TECH
BTL Industries Ltd. United Kingdom RZN 2023/20110 1 12 000 000 ₽ 12 000 000 ₽
Equipment specification total: 12 000 000 ₽

Key flagship systems of the treatment room (Hero High-Tech)

Medical Class IIa / Russian Ministry of Health registration certificate 12 000 000 ₽

BTL Emface Synchronized RF & HIFES Facial Toning System

BTL Industries Ltd. (UK) · 1.5 kW

A breakthrough method applying radiofrequency (RF) energy and high-intensity electrical stimulation (HIFES) at once to the facial muscles (zygomatic and frontal) for non-surgical lifting and elastin synthesis.

📋 4. Medical services nomenclature and clinical protocols

0 services
Code Unified directory service Market median Facilities Procedure passport
Room without medical services (ancillary)

📊 5. Comparative price benchmarking of leading resorts in Russia

Price analytics in the Knowledge Base

Summary price statistics by service category (10 resorts in Russia)

Category Min P25 Median P50 P75 Max Segment leader MEDISPA rec.
Electromagnetic stimulation 1 000 ₽ 1 600 ₽ 3 800 ₽ 10 000 ₽ 15 400 ₽ Market segment (anonymised) 15 000 ₽

💰 6. Unit economics financial model and payback scenario analysis

Payback — mo
Model scenario OCC occupancy Visits/year Revenue per year Gross profit (60%) CapEx payback
Conservative 35% 0 — — — mo
Base (MEDISPA.PRO plan) 60% 0 — — — mo
Optimistic 75% 0 — — — mo

Ancillary room: it has no procedures of its own, so revenue is not calculated.

📚 7. International evidence base (PubMed Evidence Base)

0 studies
The international evidence base is built to the gold industry standard.

🔄 8. End-to-end patient pathway and interdisciplinary synergy

4 stages
Pathway stage Linked treatment room Fire safety:
Admission diagnostics 1.2.1 Ultrasound and functional diagnostics room Screening of baseline morphofunctional status, exclusion of contraindications and mapping of treatment areas.
Medical case conference 1.1.1 Integrative preventive medicine physician's office Development of a personalised rehabilitation programme and prescription of treatment courses.
Metabolic synergy 1.3.1 Treatment room for infusion and ozone therapy (IV-Therapy) Support of the cellular antioxidant pool and mitochondrial energy metabolism to enhance response to the treatment.
Effectiveness monitoring 3.1.1 Comprehensive check-up monitoring and bioimpedance room Assessment of changes in phase angle, extracellular water balance and autonomic tone after completing the course.

📜 9. Regulatory and licensing status and medical staff requirements

2 staff roles

Russian Ministry of Health regulatory framework

Licensing by the Russian Ministry of Health: primary specialised pre-medical and medical health care in the specialities: Wellness activities.

SanPiN: SanPiN 2.1.3678-20 "Sanitary and epidemiological requirements for the operation of premises, buildings and structures in the course of medical activity", Section IV.

5P medicine & integrative concept profile:

  • M6: Cellular biogenesis, mitochondrial health & Longevity: activation of mitochondrial biogenesis (PGC-1α), optimisation of tissue...
  • M3: Endogenous biotransformation & phases of metabolic detoxification — Support for phase I and II hepatic biotransformation (cytochromes ...

Staffing and qualification requirements

Specialist physician / Preventive medicine specialist (Health improvement activities) 1.0 FTE · 2-on/2-off shift pattern

Higher medical education, a valid specialist certificate and certification in integrative preventive 5P medicine

Treatment room nurse 1.0 FTE · 2-on/2-off shift pattern

Secondary vocational medical education, 'Nursing' certificate, authorisation to perform specialised procedures

💡 10. Frequently Asked Questions & Engineering Specifications

2 verified answers

Q1 What are the space programme and MEP requirements for room Body remodelling device room and HIFEM?

The planned net usable area for room HMI.ADVA.30 (Body remodelling device room and HIFEM) is 14.0 sqm (Class V). HVAC ventilation requires 3.0 air exchanges per hour inflow and 3.0 outflow, with an electrical connected load of 3.5 kW.

Q2 What is the CapEx budget and estimated payback for room Body remodelling device room and HIFEM?

Equipment CapEx is estimated at 12 000 000 ₽, fitout at 2 310 000 ₽, with an estimated payback of 18–24 mo across 1 treatment station(s).