MEDISPA.PRO
Ministry of Health code: — Ось M0 · Интегративная медицина 5P CEBM: Level A (Аппаратная косметология)

HIFU / SMAS lifting, face

HIFU / SMAS lifting, face

Industry clinical and economic procedure passport. Full biological mechanism (MoA), patient preparation protocol, first-choice equipment fleet, integration into the resort's master treatment rooms and market price benchmarks.

Session duration
45 min
Turnover: ~60 min
Recommended course
10 sessions
допущение для расчёта экономики не задано; курс назначает врач
Throughput capacity
8 pts
per 8-hour shift
Median rate
85 425 ₽
57 262 ₽ – 107 950 ₽
Course cost
854 250 ₽
at market median
Publication volume
Level A
5 publ. in PubMed

Clinical profile

Аппаратная косметологическая процедура с высокоинтенсивным фокусированным ультразвуковым воздействием на ткани лица. В клинических публикациях изучались подъём бровей, параметры кожи и разные глубины фокусировки; результаты ниже относятся к конкретным исследованным зонам и режимам.

Каждое утверждение — со ссылкой на публикацию в списке ниже. Это срез опубликованных исследований, а не окончательная оценка метода: международная практика и интегральные протоколы часто опережают официальные публикации. Черновик по опубликованным исследованиям; требует проверки врачом. Редакция: 2026-10-26.

Mechanism of action

  • В исследованиях HIFU для лица параметры фокусировки задавались глубиной картриджа; глубина 1,5 или 3,0 мм относится к отдельному исследованному режиму, а не к универсальной настройке. [2]

Where studies show an effect

  • В исследованиях микрофокусированного ультразвука для лица оценивали подъём бровей и изменения измеряемых показателей кожи; результаты относятся к исследованным участкам и протоколам. [1, 2, 4]

Open questions and study limitations

  • Систематический обзор отмечает, что в исследованиях применялись разные настройки устройств, протоколы и уровни энергии; численные режимы отдельных публикаций не образуют единого протокола услуги. [1]
  • Данные о поверхностном HIFU для мелких морщин получены в ретроспективной оценке 30 женщин с коротким наблюдением; результаты этой группы не задают универсальный эффект для всех пациентов и аппаратов. [4]
  • В рандомизированном исследовании высоты брови сравнивали стороны лица с разной глубиной картриджа без sham-контроля; авторы указали на необходимость более крупных sham-контролируемых исследований. [2]

Safety

  • В обзоре данных MAUDE среди наиболее часто упоминавшихся сообщений были липоатрофия, неврологические явления и рубцевание; эти записи описывают сообщения о случаях и не определяют частоту осложнений. [5]

Protocol in studies

  • В рандомизированном split-face исследовании 20 взрослых получили однократную процедуру: картридж 1,5 мм применяли с одной стороны лица, а 3,0 мм — с другой; сообщалось о 225 Дж на сторону. [2]
  • В рандомизированном сравнительном исследовании микрофокусированного ультразвука и инфракрасного воздействия каждая группа получила одну процедуру; оценку проводили через 30, 60 и 90 дней. [3]
Contraindications. Противопоказания устанавливает врач с учётом состояния пациента и инструкции к конкретному аппарату; паспорт описывает данные публикаций и не заменяет врачебную оценку. Не медицинская рекомендация: показания и противопоказания определяет врач.

Equipment fleet and fit-out

Certified first-choice medical equipment and compatible device systems

Equipment registry
Base configuration (Hero Device)
Doublo HIFU (Hironic, South Korea) for ultrasonic SMAS lifting in Russia

Device platform with proven validation of the biological response. Includes built-in biofeedback sensor systems, patient protection protocols and precision dosing of exposure.

Certification: Russian Ministry of Health registration certificate / CE Medical Device Directive Class IIa/IIb.
Compatible platforms in the MEDISPA.PRO registry
Doublo HIFU (Hironic, South Korea) for ultrasonic SMAS lifting in Russia
Medical device, Roszdravnadzor registration certificate / CE
Device passport →
UTIMS A3
Medical device, Roszdravnadzor registration certificate / CE
Device passport →
Ultraformer MPT
Medical device, Roszdravnadzor registration certificate / CE
Device passport →

Architectural integration and treatment rooms

Resort rooms housing the treatment station (with SanPiN norms and MEP loads)

All treatment rooms →

Unit economics and resort price benchmarks

Market analysis based on a sample of premium sanatoriums, wellness hotels and preventive medicine clinics

Market price corridor
25th percentile (P25) 57 262 ₽
Market median 85 425 ₽
75th percentile (P75) 107 950 ₽

Median of prices in industry facilities' price lists, 2026

Basis of the price benchmark

Prices for this procedure appear in the price lists of 4 industry facilities; the median and interquartile range across facilities are shown (each facility counts once).

Procedure prices in the price directory →

Evidence base

The passport cites 5 publications verified in PubMed: systematic reviews and meta-analyses — 2, RCTs — 2, other clinical and observational studies — 0, reviews and other work — 1. The level shows how much data is published, not the value of the method.

Publication level A · Plenty of data
  1. 1.
    A Systematic Review of the Efficacy of Microfocused Ultrasound for Facial Skin Tightening.
    Int J Environ Res Public Health, 2023 · Систематический обзор · PMID 36674277
    Систематический обзор описал измеренные подъёмы бровей и уменьшение субментальной площади в исследованиях микрофокусированного ультразвука лица.
  2. 2.
    Efficacy and Safety of 1.5- and 3.0-mm High-Intensity Focused Ultrasound for Eyebrow Lifting in Korean Adults: A Prospective Randomized Split-Face Study.
    Skin Res Technol, 2026 · РКИ · PMID 42867024
    В исследовании HIFU с картриджами 1,5 и 3,0 мм к 12-й неделе зафиксировали увеличение средней высоты брови на 1,76 ± 1,19 и 1,23 ± 1,33 мм соответственно.
  3. 3.
    Effect of infrared technology on dermal thickness of the face compared to microfocused ultrasound using high frequency ultrasound skin imaging: a randomized clinical trial.
    J Cosmet Laser Ther, 2026 · РКИ · PMID 42446436
    В рандомизированном сравнении микрофокусированного ультразвука и инфракрасной технологии авторы сообщили об увеличении дермальной толщины примерно на 40% в обеих группах.
  4. 4.
    Clinical Efficacy and Safety of Shallow-Dermal Linear HIFU for Fine-Wrinkle Reduction in Asian Skin.
    J Craniofac Surg, 2026 · Исследование · PMID 41940941
    В ретроспективной оценке поверхностного линейного HIFU через 12 недель измеренная глубина морщин и шероховатость кожи снизились, а показатели эластичности увеличились.
  5. 5.
    Microfocused Ultrasound With Visualization: A Systematic Review of Adverse Events and Risk of Subsequent Facelift Compromise.
    Dermatol Surg, 2025 · Систематический обзор · PMID 39625163
    Систематический обзор извлёк 106 сообщений из базы MAUDE; среди наиболее часто упоминавшихся в них событий были липоатрофия, неврологические явления и рубцевание.

Publications were found in PubMed; titles and journals are given verbatim, conclusions are a brief summary of the abstracts under the conditions of the specific studies. The level shows the volume of published data, not the value of the method: A — Plenty of data: consistent systematic reviews and meta-analyses of RCTs; B — Some data: reviews or several RCTs, results are heterogeneous; C — Little data: single RCTs or controlled studies; D — Scarce data: mainly reviews, observational and experimental studies. The passport is updated as new work is published and with regard to international practice.