Polysomnography and cardiorespiratory sleep monitoring

Polysomnography and Home Sleep Apnea Testing

Industry clinical and economic procedure passport. Full biological mechanism (MoA), patient preparation protocol, first-choice equipment fleet, integration into the resort's master treatment rooms and market price benchmarks.

Session duration
480 min
Turnover: ~495 min
Recommended course
1 sessions
1 treatments – an assumption for the economic calculation; the course is prescribed by a physician
Throughput capacity
1 pts
per 8-hour shift
Median rate
21 250 ₽
17 250 ₽ – 27 225 ₽
Course cost
21 250 ₽
at market median
Publication volume
Level A
5 publ. in PubMed

Clinical profile

Overnight recording of breathing, blood oxygen saturation, heart rhythm and (with polysomnography) sleep stages to diagnose obstructive sleep apnoea. Use is set by clinical guidelines: polysomnography is the standard, and a home test is acceptable in patients without complicating conditions; questionnaires and wearables do not replace diagnosis.

Every statement links to a publication in the list below. This is a snapshot of published research, not a final assessment of the method: international practice and integrated protocols often run ahead of official publications. Draft based on published research; requires review by a physician. Revision: 2026-10-17.

Where studies show an effect

  • Suspected obstructive sleep apnoea after clinical assessment: polysomnography is the standard diagnostic test. [1]
  • Without complicating conditions and with signs of moderate to severe apnoea, a home test with a technically adequate device is acceptable. [1]
  • Sleep apnoea is widespread and in most cases undiagnosed. [3]

Open questions and study limitations

  • Questionnaires and prediction scales should not be used for diagnosis without polysomnography or a home test; after a negative or inconclusive home test, polysomnography is needed. [1]
  • AI-based wearables are not yet reliable enough and should be used alongside conventional diagnostics. [5]
  • A home test is unsuitable in significant cardiopulmonary disease, respiratory muscle weakness, hypoventilation, opioid use, history of stroke and severe insomnia — polysomnography is needed. [1]

Protocol in studies

  • For screening, the STOP-Bang questionnaire is more accurate than the Berlin questionnaire, STOP and the Epworth scale. [4]
Contraindications. The choice between polysomnography and a home test is made by a sleep physician according to clinical guidelines.

Equipment fleet and fit-out

Certified first-choice medical equipment and compatible device systems

Equipment registry
Base configuration (Hero Device)
Polysomnography system / cardiorespiratory monitor

Device platform with proven validation of the biological response. Includes built-in biofeedback sensor systems, patient protection protocols and precision dosing of exposure.

Certification: Russian Ministry of Health registration certificate / CE Medical Device Directive Class IIa/IIb.
Compatible platforms in the MEDISPA.PRO registry
SAMOA Lite device for detecting and monitoring sleep-disordered breathing
Medical device, Roszdravnadzor registration certificate / CE
In the registry →

Architectural integration and treatment rooms

Resort rooms housing the treatment station (with SanPiN norms and MEP loads)

All treatment rooms →

Unit economics and resort price benchmarks

Market analysis based on a sample of premium sanatoriums, wellness hotels and preventive medicine clinics

Market price corridor
25th percentile (P25) 17 250 ₽
Market median 21 250 ₽
75th percentile (P75) 27 225 ₽

Median of prices in industry facilities' price lists, 2026

Basis of the price benchmark

Prices for this procedure appear in the price lists of 4 industry facilities; the median and interquartile range across facilities are shown (each facility counts once).

Evidence base

Use is governed by clinical guidelines based on a systematic review using GRADE.

Publication level A · Plenty of data
  1. 1.
    Clinical Practice Guideline for Diagnostic Testing for Adult Obstructive Sleep Apnea: An American Academy of Sleep Medicine Clinical Practice Guideline.
    J Clin Sleep Med, 2017 · AASM clinical guideline · PMID 28162150
    Polysomnography is the standard; a home test is acceptable in patients without complications; questionnaires do not replace the test.
  2. 2.
    Clinical guideline for the evaluation, management and long-term care of obstructive sleep apnea in adults.
    J Clin Sleep Med, 2009 · Clinical guideline · PMID 19960649
    Evaluation, management and long-term care of sleep apnoea in adults.
  3. 3.
    Unmasking obstructive sleep apnea: Estimated prevalence and impact in the United States.
    Respir Med, 2025 · Systematic review · PMID 40957495
    Sleep apnoea is widespread among adults in the USA and mostly undiagnosed.
  4. 4.
    Diagnostic accuracy of the Berlin questionnaire, STOP-BANG, STOP, and Epworth sleepiness scale in detecting obstructive sleep apnea: A bivariate meta-analysis.
    Sleep Med Rev, 2017 · Diagnostic accuracy meta-analysis · PMID 27919588
    For detecting apnoea, the STOP-Bang questionnaire is more accurate than the Berlin, STOP and Epworth scales.
  5. 5.
    Detection of Sleep Apnea Using Wearable AI: Systematic Review and Meta-Analysis.
    J Med Internet Res, 2024 · Systematic review and meta-analysis · PMID 39255014
    AI-based wearables are not yet accurate enough for routine apnoea diagnosis.

Publications were found in PubMed; titles and journals are given verbatim, conclusions are a brief summary of the abstracts under the conditions of the specific studies. The level shows the volume of published data, not the value of the method: A — Plenty of data: consistent systematic reviews and meta-analyses of RCTs; B — Some data: reviews or several RCTs, results are heterogeneous; C — Little data: single RCTs or controlled studies; D — Scarce data: mainly reviews, observational and experimental studies. The passport is updated as new work is published and with regard to international practice.