MEDISPA.PRO
Ministry of Health code: — Axis M5 · Cardiometabolic health and microcirculation CEBM: Level A (Гинекология и урология)

Urological vacuum device therapy

Urological vacuum device therapy

Industry clinical and economic procedure passport. Full biological mechanism (MoA), patient preparation protocol, first-choice equipment fleet, integration into the resort's master treatment rooms and market price benchmarks.

Session duration
15 min
Turnover: ~30 min
Recommended course
10 sessions
Ежедневно в течение не менее тридцати дней перед операцией в конкретном рандомизированном исследовании. — допущение для расчёта экономики; курс назначает врач
Throughput capacity
16 pts
per 8-hour shift
Median rate
800 ₽
750 ₽ – 800 ₽
Course cost
8 000 ₽
at market median
Publication volume
Level A
4 publ. in PubMed

Clinical profile

Аппарат создаёт отрицательное давление для наполнения кавернозных тел кровью. Исследования вакуумных устройств при эректильной дисфункции описывают изменения показателей эректильной функции и длины полового члена в отдельных популяциях. Данные о вакуумной терапии не устанавливают эффект электростимуляции, которая также входит в объединённую услугу справочника.

Каждое утверждение — со ссылкой на публикацию в списке ниже. Это срез опубликованных исследований, а не окончательная оценка метода: международная практика и интегральные протоколы часто опережают официальные публикации. Черновик по опубликованным исследованиям; требует проверки врачом. Редакция: 2026-10-26.

Mechanism of action

  • Вакуумная помпа создаёт отрицательное давление вокруг полового члена и способствует поступлению крови в кавернозные тела. [1]

Where studies show an effect

  • В метаанализе при эректильной дисфункции вакуумная терапия в сравнении с отсутствием вмешательства была связана с более высокими показателями эректильной функции по шкале IIEF. [1]
  • У пациентов с резистентной эректильной дисфункцией метаанализ описал успешность полового акта и удовлетворённость на фоне применения вакуумного устройства в изученных работах. [2]
  • После нервосберегающей простатэктомии рандомизированное исследование сообщило о сохранении длины полового члена в группах с вакуумным устройством; дополнительное изменение показателя IIEF-5 описано для сочетания устройства с тадалафилом. [3]

Open questions and study limitations

  • После простатэктомии рандомизированное исследование не обнаружило различий между группами по возвращению к целевой эректильной функции спустя двенадцать месяцев. [3]
  • Обзор резистентной эректильной дисфункции указывает на необходимость более крупных рандомизированных исследований с длительным наблюдением; его объединённая оценка не является сравнением с имитацией процедуры. [2]
  • Исследования вакуумных устройств в приведённой подборке не оценивают электростимуляционную составляющую объединённой услуги. [1, 2, 3]

Safety

  • В метаанализе при резистентной эректильной дисфункции наиболее частым описанным нежелательным явлением были кровоподтёки полового члена. [2]

Protocol in studies

  • В предоперационном рандомизированном исследовании применяли вакуумное устройство по 10–15 минут ежедневно не менее 30 дней. [4]
Contraindications. Показания и противопоказания, включая выбор аппаратного режима, определяет профильный врач индивидуально; приведённые режимы исследований не являются назначением. Не медицинская рекомендация: показания и противопоказания определяет врач.

Equipment fleet and fit-out

Certified first-choice medical equipment and compatible device systems

Equipment registry
Base configuration (Hero Device)
"Andro-Gyn" device

Device platform with proven validation of the biological response. Includes built-in biofeedback sensor systems, patient protection protocols and precision dosing of exposure.

Certification: Russian Ministry of Health registration certificate / CE Medical Device Directive Class IIa/IIb.
Compatible platforms in the MEDISPA.PRO registry
"Ivavita" vacuum therapy device
Medical device, Roszdravnadzor registration certificate / CE
Device passport →
"Andro-Gyn" device
Medical device, Roszdravnadzor registration certificate / CE
Device passport →

Architectural integration and treatment rooms

Resort rooms housing the treatment station (with SanPiN norms and MEP loads)

All treatment rooms →

Unit economics and resort price benchmarks

Market analysis based on a sample of premium sanatoriums, wellness hotels and preventive medicine clinics

Market price corridor
25th percentile (P25) 750 ₽
Market median 800 ₽
75th percentile (P75) 800 ₽

Median of prices in industry facilities' price lists, 2026

Basis of the price benchmark

Prices for this procedure appear in the price lists of 3 industry facilities; the median and interquartile range across facilities are shown (each facility counts once).

Procedure prices in the price directory →

Evidence base

The passport cites 4 publications verified in PubMed: systematic reviews and meta-analyses — 2, RCTs — 2, other clinical and observational studies — 0, reviews and other work — 0. The level shows how much data is published, not the value of the method.

Publication level A · Plenty of data
  1. 1.
    Is the vacuum erectile device suitable for treating erectile dysfunction? A systematic review and meta-analysis exploring the evidence gap.
    Arch Ital Urol Androl, 2025 · Мета-анализ · PMID 41147931
    Метаанализ сообщает об изменении IIEF при применении вакуумного устройства по сравнению с отсутствием вмешательства; описывает создание отрицательного давления.
  2. 2.
    Efficacy of vacuum erectile device in refractory erectile dysfunction: a systematic review and meta-analysis.
    Int J Impot Res, 2026 · Мета-анализ · PMID 40542251
    Метаанализ пациентов с резистентной эректильной дисфункцией сообщил об исходах полового акта и кровоподтёках; авторы запросили более крупные РКИ.
  3. 3.
    A prospective randomized controlled study on scheduled PDE5i and vacuum erectile devices in the treatment of erectile dysfunction after nerve sparing prostatectomy.
    Asian J Androl, 2022 · РКИ · PMID 34975069
    В РКИ после нервосберегающей простатэктомии применение устройства было связано с сохранением длины; различий в возвращении к целевой функции между группами не было.
  4. 4.
    Is the daily use of vacuum erection device for a month before penile prosthesis implantation beneficial? a randomized controlled trial.
    Andrology, 2017 · РКИ · PMID 27654466
    Предоперационное РКИ изучало применение устройства по 10–15 минут ежедневно не менее тридцати дней и оценивало длину до операции.

Publications were found in PubMed; titles and journals are given verbatim, conclusions are a brief summary of the abstracts under the conditions of the specific studies. The level shows the volume of published data, not the value of the method: A — Plenty of data: consistent systematic reviews and meta-analyses of RCTs; B — Some data: reviews or several RCTs, results are heterogeneous; C — Little data: single RCTs or controlled studies; D — Scarce data: mainly reviews, observational and experimental studies. The passport is updated as new work is published and with regard to international practice.