Room 2.7.10 · Lap pool
Industry analytical passport of room type Hydro-balneological spa complex. Full profile of architectural TEP, medical equipment specification (CapEx), MEP engineering loads (HVAC, electrical, water supply and drainage), resort price benchmarks and unit economics financial model.
Thermal-zone brick: norms and capacity
industry normsThe brick is self-sufficient and not part of the typical project: area is a range where the norms give one, climate and MEP follow industry norms, capacity is a set of scenarios from real resorts.
130–312.5 m²
water surface, without walkways and hall
Capacity per norms, persons: 10
- Water temperature
- 27–29 °C
- Water depth
- 1–1.2 m
- Water turnover, at most
- ≤ 4 h
- Pool-hall air temperature
- 24–28 °C
- Hall air warmer than the water by
- 1–2 °C
Capacity: scenarios from real resorts, places
Data is being collected: the scenarios appear once capacities of real resorts are in.
Industry norms, our wording · climate of all zones in the SPA section
🏛 1. Architectural and planning parameters and zoning
Total area: 0.0 m²Building requirements and finishing materials (SanPiN)
⚡ 2. Engineering and technology profile (MEP)
ЭОМ 3.0 кВт · ОВиК —/—Electrical (power supply)
- Installed power:
- 3.0 kW
- Design power (Kd=0.72):
- 2.25 kW
- Cable lines:
- 1 beams
- Distribution board:
- 230V / 50Hz
- Residual current protection (RCD):
- УЗО 10мА/30мА медицинского типа
- Medical UPS:
- Not required
HVAC (ventilation & SanPiN)
- SanPiN cleanliness class:
- —
- Supply air exchange:
- —
- Exhaust air exchange:
- —
- Temperature:
- вода 27–29 °C; зал 24–28 °C
- Humidity:
- —
- Gas destruction:
- General ventilation filtration
Water supply & drainage and safety
- Cold/hot water points:
- 1 stations (elbow-operated)
- Floor drains:
- 1 pcs (dry trap)
- Water treatment:
- Standard cold water filtration
- Clinical and technological rationale for synergy
- Automatic fire alarm, type 2-3 warning and evacuation system, powder/gas fire extinguishers
- Nurse call system:
- Installed at stations
🔬 3. Medical and spa equipment specification (CapEx)
—| № | Equipment name | Brand / Manufacturer | Country | Ministry of Health registration certificate | Qty | Unit price | Amount (CapEx) |
|---|---|---|---|---|---|---|---|
| Equipment specification total: | — | ||||||
📋 4. Medical services nomenclature and clinical protocols
1 services| Code | Unified directory service | Market median | Facilities | Procedure passport |
|---|---|---|---|---|
| — | Посещение бассейна (разовое) | 800 ₽ | 3 | — |
📊 5. Comparative price benchmarking of leading resorts in Russia
Price analytics in the Knowledge BaseSummary price statistics by service category (10 resorts in Russia)
| Category | Min | P25 | Median P50 | P75 | Max | Segment leader | MEDISPA rec. |
|---|---|---|---|---|---|---|---|
| Clinical consultation | 1 000 ₽ | 2 900 ₽ | 4 500 ₽ | 6 800 ₽ | 9 750 ₽ | Medical Spa / Premium segment | 7 150 ₽ |
💰 6. Unit economics financial model and payback scenario analysis
Payback 0.0 mo| Model scenario | OCC occupancy | Visits/year | Revenue per year | Gross profit (60%) | CapEx payback |
|---|---|---|---|---|---|
| Conservative | 35% | 1 260 | 1 008 000 ₽ | 604 800 ₽ | 0.0 mo |
| Base (MEDISPA.PRO plan) | 60% | 2 160 | 1 728 000 ₽ | 1 036 800 ₽ | 0.0 mo |
| Optimistic | 75% | 2 700 | 2 160 000 ₽ | 1 296 000 ₽ | 0.0 mo |
Calculated from the room's procedures: average ticket 800 ₽ is the mean of the market medians of 1 of 1 profile procedures; average slot 60 min including service time (norm 30 / 60 min, special procedures by duration); capacity 1 station × 10 h × 360 days (300 h per month = 100 % utilisation) = 3 600 sessions per year. Session duration and margin are planning assumptions.
📚 7. International evidence base (PubMed Evidence Base)
2 studies🔄 8. End-to-end patient pathway and interdisciplinary synergy
4 stages| Pathway stage | Linked treatment room | Fire safety: |
|---|---|---|
| Admission diagnostics | 1.2.1 Ultrasound and functional diagnostics room | Screening of baseline morphofunctional status, exclusion of contraindications and mapping of treatment areas. |
| Medical case conference | 1.1.1 Integrative preventive medicine physician's office | Development of a personalised rehabilitation programme and prescription of treatment courses. |
| Metabolic synergy | 1.3.1 Treatment room for infusion and ozone therapy (IV-Therapy) | Support of the cellular antioxidant pool and mitochondrial energy metabolism to enhance response to the treatment. |
| Effectiveness monitoring | 3.1.1 Comprehensive check-up monitoring and bioimpedance room | Assessment of changes in phase angle, extracellular water balance and autonomic tone after completing the course. |
📜 9. Regulatory and licensing status and medical staff requirements
0 штатных ролейRussian Ministry of Health regulatory framework
Wellness activity; a thermal-zone brick needs no medical licence.
SanPiN: Industry norms of the thermal zone (climate, MEP, water hygiene); Russian norms as they are collected.
5P medicine & integrative concept profile:
- M0: Основы интегративной превентивной медицины
- M6: Клеточный биогенез, митохондриальное здоровье & Longevity
Staffing and qualification requirements
💡 10. Frequently Asked Questions & Engineering Specifications
3 verified answersQ1 What climate does the Lap pool need?
Per industry norms: Water temperature: 27–29 °C.
Q2 What area and capacity does the Lap pool have?
Per industry norms: 130–312.5 m² (water surface, without walkways and hall). Capacities of real resorts are being collected: minimum, mean, median and maximum will appear on this page.
Q3 What MEP and equipment does the Lap pool need?
MEP: Water depth: 1–1.2 m; Water turnover, at most: ≤ 4 h; Pool-hall air temperature: 24–28 °C; Hall air warmer than the water by: 1–2 °C. Equipment: Pool filter (sand / glass / cartridge / membrane), Pool circulation pump, Disinfection and dosing: chlorine, pH, UV, ozone, electrolysis, Pool heat exchanger, Pool-hall dehumidifier / air-handling unit, Pool cover, Water-quality analyser / controller.