MEDISPA.PRO
2.7.10 2.7 · Thermal zone: heat cabins, cold, showers, pools and relaxation (Термальная зона)

Room 2.7.10 · Lap pool

Industry analytical passport of room type Hydro-balneological spa complex. Full profile of architectural TEP, medical equipment specification (CapEx), MEP engineering loads (HVAC, electrical, water supply and drainage), resort price benchmarks and unit economics financial model.

Net usable area NUA
130–312,5 м²
range per industry norms
Treatment stations
1 station
Type: T5
Equipment CapEx
—
0 items
CapEx Finishes / MEP
—
—
Total investment
—
Turnkey incl. VAT
Payback period
— mo
Base scenario

Thermal-zone brick: norms and capacity

industry norms

The brick is self-sufficient and not part of the typical project: area is a range where the norms give one, climate and MEP follow industry norms, capacity is a set of scenarios from real resorts.

Area

130–312.5 m²

water surface, without walkways and hall

Capacity per norms, persons: 10

Climate
Water temperature
27–29 °C
MEP and plant space
Water depth
1–1.2 m
Water turnover, at most
≤ 4 h
Pool-hall air temperature
24–28 °C
Hall air warmer than the water by
1–2 °C

Capacity: scenarios from real resorts, places

Minimum—
Mean—
Median—
Maximum—

Data is being collected: the scenarios appear once capacities of real resorts are in.

Equipment classes
Pool filter (sand / glass / cartridge / membrane)Pool circulation pumpDisinfection and dosing: chlorine, pH, UV, ozone, electrolysisPool heat exchangerPool-hall dehumidifier / air-handling unitPool coverWater-quality analyser / controller

Industry norms, our wording · climate of all zones in the SPA section

🏛 1. Architectural and planning parameters and zoning

Total area: 0.0 m²

Building requirements and finishing materials (SanPiN)

Cleanliness class:—
Wet point:Required (cold + hot water + drain)
Ceiling height:≥ 3.0 m (clear height)
Door opening width:≥ 1.0–1.2 m (medical standard)
Floor covering:Homogeneous antistatic linoleum
Wall finish:Moisture-resistant paint / disinfectant resistance

⚡ 2. Engineering and technology profile (MEP)

ЭОМ 3.0 кВт · ОВиК —/—

Electrical (power supply)

Installed power:
3.0 kW
Design power (Kd=0.72):
2.25 kW
Cable lines:
1 beams
Distribution board:
230V / 50Hz
Residual current protection (RCD):
УЗО 10мА/30мА медицинского типа
Medical UPS:
Not required

HVAC (ventilation & SanPiN)

SanPiN cleanliness class:
—
Supply air exchange:
—
Exhaust air exchange:
—
Temperature:
вода 27–29 °C; зал 24–28 °C
Humidity:
—
Gas destruction:
General ventilation filtration

Water supply & drainage and safety

Cold/hot water points:
1 stations (elbow-operated)
Floor drains:
1 pcs (dry trap)
Water treatment:
Standard cold water filtration
Clinical and technological rationale for synergy
Automatic fire alarm, type 2-3 warning and evacuation system, powder/gas fire extinguishers
Nurse call system:
Installed at stations

🔬 3. Medical and spa equipment specification (CapEx)

—
№ Equipment name Brand / Manufacturer Country Ministry of Health registration certificate Qty Unit price Amount (CapEx)
Equipment specification total: —

📋 4. Medical services nomenclature and clinical protocols

1 services
Code Unified directory service Market median Facilities Procedure passport
— Посещение бассейна (разовое) 800 ₽ 3 —

📊 5. Comparative price benchmarking of leading resorts in Russia

Price analytics in the Knowledge Base

Summary price statistics by service category (10 resorts in Russia)

Category Min P25 Median P50 P75 Max Segment leader MEDISPA rec.
Clinical consultation 1 000 ₽ 2 900 ₽ 4 500 ₽ 6 800 ₽ 9 750 ₽ Medical Spa / Premium segment 7 150 ₽

💰 6. Unit economics financial model and payback scenario analysis

Payback 0.0 mo
Model scenario OCC occupancy Visits/year Revenue per year Gross profit (60%) CapEx payback
Conservative 35% 1 260 1 008 000 ₽ 604 800 ₽ 0.0 mo
Base (MEDISPA.PRO plan) 60% 2 160 1 728 000 ₽ 1 036 800 ₽ 0.0 mo
Optimistic 75% 2 700 2 160 000 ₽ 1 296 000 ₽ 0.0 mo

Calculated from the room's procedures: average ticket 800 ₽ is the mean of the market medians of 1 of 1 profile procedures; average slot 60 min including service time (norm 30 / 60 min, special procedures by duration); capacity 1 station × 10 h × 360 days (300 h per month = 100 % utilisation) = 3 600 sessions per year. Session duration and margin are planning assumptions.

📚 7. International evidence base (PubMed Evidence Base)

2 studies

🔄 8. End-to-end patient pathway and interdisciplinary synergy

4 stages
Pathway stage Linked treatment room Fire safety:
Admission diagnostics 1.2.1 Ultrasound and functional diagnostics room Screening of baseline morphofunctional status, exclusion of contraindications and mapping of treatment areas.
Medical case conference 1.1.1 Integrative preventive medicine physician's office Development of a personalised rehabilitation programme and prescription of treatment courses.
Metabolic synergy 1.3.1 Treatment room for infusion and ozone therapy (IV-Therapy) Support of the cellular antioxidant pool and mitochondrial energy metabolism to enhance response to the treatment.
Effectiveness monitoring 3.1.1 Comprehensive check-up monitoring and bioimpedance room Assessment of changes in phase angle, extracellular water balance and autonomic tone after completing the course.

📜 9. Regulatory and licensing status and medical staff requirements

0 штатных ролей

Russian Ministry of Health regulatory framework

Wellness activity; a thermal-zone brick needs no medical licence.

SanPiN: Industry norms of the thermal zone (climate, MEP, water hygiene); Russian norms as they are collected.

5P medicine & integrative concept profile:

  • M0: Основы интегративной превентивной медицины
  • M6: Клеточный биогенез, митохондриальное здоровье & Longevity

Staffing and qualification requirements

💡 10. Frequently Asked Questions & Engineering Specifications

3 verified answers

Q1 What climate does the Lap pool need?

Per industry norms: Water temperature: 27–29 °C.

Q2 What area and capacity does the Lap pool have?

Per industry norms: 130–312.5 m² (water surface, without walkways and hall). Capacities of real resorts are being collected: minimum, mean, median and maximum will appear on this page.

Q3 What MEP and equipment does the Lap pool need?

MEP: Water depth: 1–1.2 m; Water turnover, at most: ≤ 4 h; Pool-hall air temperature: 24–28 °C; Hall air warmer than the water by: 1–2 °C. Equipment: Pool filter (sand / glass / cartridge / membrane), Pool circulation pump, Disinfection and dosing: chlorine, pH, UV, ozone, electrolysis, Pool heat exchanger, Pool-hall dehumidifier / air-handling unit, Pool cover, Water-quality analyser / controller.