MEDISPA.PRO
Ministry of Health code: A04.28.002.003 Axis M0 · Introductory check-up and longevity biomarkers CEBM: Level B (УЗИ и лучевая диагностика)

Bladder ultrasound (post-void residual volume)

Bladder ultrasound (post-void residual volume)

Industry clinical and economic procedure passport. Full biological mechanism (MoA), patient preparation protocol, first-choice equipment fleet, integration into the resort's master treatment rooms and market price benchmarks.

Session duration
45 min
Turnover: ~60 min
Recommended course
100 sessions
сразу после мочеиспускания; при объёме меньше 100 мл — повторное сканирование — допущение для расчёта экономики; курс назначает врач
Throughput capacity
8 pts
per 8-hour shift
Median rate
1 500 ₽
1 400 ₽ – 2 650 ₽
Course cost
150 000 ₽
at market median
Publication volume
Level B
4 publ. in PubMed

Clinical profile

Ультразвуковое исследование мочевого пузыря: объём наполнения, остаточная моча после мочеиспускания, толщина стенки. В публикациях 2011–2025 годов объём по УЗИ и портативным сканерам сопоставлен с катетеризацией, а толщина стенки пузыря изучена как признак инфравезикальной обструкции (систематический обзор и мета-анализ 2023 года).

Каждое утверждение — со ссылкой на публикацию в списке ниже. Это срез опубликованных исследований, а не окончательная оценка метода: международная практика и интегральные протоколы часто опережают официальные публикации. Черновик по опубликованным исследованиям; требует проверки врачом. Редакция: 2026-10-31.

Mechanism of action

  • Толщина стенки детрузора и ультразвуковая расчётная масса пузыря отражают перестройку стенки при затруднённом оттоке мочи; в мета-анализе толщина детрузора показала высокую специфичность, расчётная масса — высокую чувствительность. [1]

Where studies show an effect

  • Измерение остаточной мочи: в обзоре 22 исследований (2025) клинически значимой разницы объёма при катетеризации, портативном сканере и стандартном УЗИ не найдено. [2]
  • Инфравезикальная обструкция у пациентов с симптомами нижних мочевых путей: по 10 исследованиям толщины детрузора объединённая чувствительность 0,68 и специфичность 0,91. [1]
  • После радикальной гистерэктомии при пороге 100 мл сканирование совпадало с катетеризацией в 90 % случаев, а повторное сканирование при объёме меньше 100 мл дало специфичность 97,2 %. [3]

Open questions and study limitations

  • Исследования толщины стенки неоднородны (I² 83–93 %); авторы мета-анализа указывают на необходимость новых исследований хорошего дизайна. [1]
  • Портативные сканеры без предварительного изображения завышали объём больше 100 мл в среднем на 16,3 %, сканер с изображением занижал на 14,1 %. [4]

Protocol in studies

  • В сравнительном исследовании остаточную мочу измеряли трижды двумя исследователями, затем сразу выполняли катетеризацию для определения истинного объёма. [4]
Contraindications. Условия измерения (наполнение пузыря, время после мочеиспускания) и трактовку результата определяет врач. Не медицинская рекомендация: показания и противопоказания определяет врач.

Equipment fleet and fit-out

Certified first-choice medical equipment and compatible device systems

Equipment registry
Base configuration (Hero Device)
Ultrasound diagnostic system with vaginal probe

Device platform with proven validation of the biological response. Includes built-in biofeedback sensor systems, patient protection protocols and precision dosing of exposure.

Certification: Russian Ministry of Health registration certificate / CE Medical Device Directive Class IIa/IIb.
Compatible platforms in the MEDISPA.PRO registry
Logiq S8 medical ultrasound diagnostic system
Medical device, Roszdravnadzor registration certificate / CE
Device passport →

Architectural integration and treatment rooms

Resort rooms housing the treatment station (with SanPiN norms and MEP loads)

All treatment rooms →

Unit economics and resort price benchmarks

Market analysis based on a sample of premium sanatoriums, wellness hotels and preventive medicine clinics

Market price corridor
25th percentile (P25) 1 400 ₽
Market median 1 500 ₽
75th percentile (P75) 2 650 ₽

Median of prices in industry facilities' price lists, 2026

Basis of the price benchmark

Prices for this procedure appear in the price lists of 7 industry facilities; the median and interquartile range across facilities are shown (each facility counts once).

Procedure prices in the price directory →

Evidence base

The passport cites 4 publications verified in PubMed: systematic reviews and meta-analyses — 1, RCTs — 0, other clinical and observational studies — 1, reviews and other work — 2. The level shows how much data is published, not the value of the method.

Publication level B · Some data
  1. 1.
    Bladder Sonomorphological Tests in Diagnosing Bladder Outlet Obstruction in Patients with Lower Urinary Tract Symptoms: A Systematic Review and Meta-Analysis.
    Urol Int, 2023 · Мета-анализ · PMID 34903702
    Мета-анализ: толщина детрузора по УЗИ выявляла инфравезикальную обструкцию с чувствительностью 0,68 и специфичностью 0,91, расчётная масса пузыря — 0,88 и 0,81.
  2. 2.
    Post-void residual measurement: A comprehensive review of the clinical relevance and precision of bladder scanner devices.
    Fr J Urol, 2025 · Обзор · PMID 39983905
    Обзор 22 исследований: объём пузыря при катетеризации, портативном сканере и стандартном УЗИ клинически значимо не различался.
  3. 3.
    Accuracy of Post-Void Residual Urine Volume Measurement Using an Ultrasound Bladder Scanner among Postoperative Radical Hysterectomy Patients.
    J Med Assoc Thai, 2016 · Исследование · PMID 29952185
    После радикальной гистерэктомии сканер при пороге 100 мл совпадал с катетеризацией в 90 % случаев; повторный скан дал специфичность 97,2 %.
  4. 4.
    Accuracy of post-void residual urine volume measurement using a portable ultrasound bladder scanner with real-time pre-scan imaging.
    Neurourol Urodyn, 2011 · Сравнительное исследование · PMID 20658544
    У 67 пациентов корреляция объёма по сканеру с катетеризацией составила 0,932–0,950; предварительное изображение уменьшало разброс измерений.

Publications were found in PubMed; titles and journals are given verbatim, conclusions are a brief summary of the abstracts under the conditions of the specific studies. The level shows the volume of published data, not the value of the method: A — Plenty of data: consistent systematic reviews and meta-analyses of RCTs; B — Some data: reviews or several RCTs, results are heterogeneous; C — Little data: single RCTs or controlled studies; D — Scarce data: mainly reviews, observational and experimental studies. The passport is updated as new work is published and with regard to international practice.