MEDISPA.PRO
Ministry of Health code: A04.12.006.001 Axis M5 · Cardiometabolic health and microcirculation CEBM: Level B (УЗИ и лучевая диагностика)

Lower-limb arterial duplex ultrasound

Lower-limb arterial duplex ultrasound

Industry clinical and economic procedure passport. Full biological mechanism (MoA), patient preparation protocol, first-choice equipment fleet, integration into the resort's master treatment rooms and market price benchmarks.

Session duration
45 min
Turnover: ~60 min
Recommended course
9 sessions
в РКИ наблюдения после шунтирования — через 1, 3, 6, 9 и 12 месяцев после операции — допущение для расчёта экономики; курс назначает врач
Throughput capacity
8 pts
per 8-hour shift
Median rate
4 500 ₽
4 200 ₽ – 5 950 ₽
Course cost
40 500 ₽
at market median
Publication volume
Level B
4 publ. in PubMed

Clinical profile

Дуплексное сканирование артерий ног: изображение просвета и стенки сосуда в сочетании со спектральным анализом скорости кровотока для выявления стенозов и окклюзий при заболевании периферических артерий. Мета-анализы 1996 и 2025 годов сравнили метод с ангиографией по сегментам артерий; изучены также время ускорения кровотока в артериях стопы и наблюдение за шунтами.

Каждое утверждение — со ссылкой на публикацию в списке ниже. Это срез опубликованных исследований, а не окончательная оценка метода: международная практика и интегральные протоколы часто опережают официальные публикации. Черновик по опубликованным исследованиям; требует проверки врачом. Редакция: 2026-10-31.

Mechanism of action

  • Время ускорения кровотока в артериях стопы измеряют по допплеровской кривой от начала до пика систолы; в мета-анализе 2026 года показатель выявлял значимую ишемию конечности в сравнении с лодыжечно-плечевым индексом, удлинение времени было связано с худшим заживлением ран. [3]

Where studies show an effect

  • Симптомное заболевание периферических артерий: в мета-анализе 15 исследований (9067 артерий, 2025) чувствительность дуплексного сканирования 0,86, специфичность 0,95 по сравнению с ангиографией; точнее всего — в бедренно-подколенном сегменте. [1]
  • В мета-анализе 1996 года для стеноза не менее 50 % или окклюзии в подвздошном сегменте чувствительность составила 86 %, специфичность 97 %, в бедренно-подколенном — 80 % и 96 %. [2]
  • При хронической угрожающей потере конечности время ускорения кровотока в артериях стопы изучено как дополнение к другим тестам перфузии. [3]

Open questions and study limitations

  • Ниже колена точность ниже (чувствительность 0,78); большинство исследований имеют высокий или неясный риск систематической ошибки и выраженную неоднородность. [1]
  • В РКИ 1998 года (179 пациентов после шунтирования вен ниже паховой связки) добавление дуплексного сканирования к клиническому наблюдению не улучшило первичную проходимость шунтов за год. [4]

Protocol in studies

  • В РКИ одна группа наблюдалась по клиническому осмотру и лодыжечно-плечевому индексу, другая — с дополнительным цветовым дуплексным сканированием шунта. [4]
Contraindications. Показания, объём исследования и необходимость ангиографии определяет врач (сосудистый хирург, кардиолог). Не медицинская рекомендация: показания и противопоказания определяет врач.

Equipment fleet and fit-out

Certified first-choice medical equipment and compatible device systems

Equipment registry
Base configuration (Hero Device)
Ultrasound diagnostic system with vaginal probe

Device platform with proven validation of the biological response. Includes built-in biofeedback sensor systems, patient protection protocols and precision dosing of exposure.

Certification: Russian Ministry of Health registration certificate / CE Medical Device Directive Class IIa/IIb.
Compatible platforms in the MEDISPA.PRO registry
Logiq S8 medical ultrasound diagnostic system
Medical device, Roszdravnadzor registration certificate / CE
Device passport →

Architectural integration and treatment rooms

Resort rooms housing the treatment station (with SanPiN norms and MEP loads)

All treatment rooms →

Unit economics and resort price benchmarks

Market analysis based on a sample of premium sanatoriums, wellness hotels and preventive medicine clinics

Market price corridor
25th percentile (P25) 4 200 ₽
Market median 4 500 ₽
75th percentile (P75) 5 950 ₽

Median of prices in industry facilities' price lists, 2026

Basis of the price benchmark

Prices for this procedure appear in the price lists of 5 industry facilities; the median and interquartile range across facilities are shown (each facility counts once).

Procedure prices in the price directory →

Evidence base

The passport cites 4 publications verified in PubMed: systematic reviews and meta-analyses — 1, RCTs — 1, other clinical and observational studies — 0, reviews and other work — 2. The level shows how much data is published, not the value of the method.

Publication level B · Some data
  1. 1.
    Accuracy of duplex ultrasound in peripheral artery disease: a systematic review and meta-analysis.
    J Vasc Bras, 2025 · Обзор · PMID 39981417
    Мета-анализ 15 исследований (9067 артерий): чувствительность дуплексного сканирования 0,86, специфичность 0,95; ниже колена — 0,78 и 0,92.
  2. 2.
    Diagnosis of arterial disease of the lower extremities with duplex ultrasonography.
    Br J Surg, 1996 · Обзор · PMID 8665208
    Мета-анализ 16 исследований: в подвздошном сегменте чувствительность 86 % и специфичность 97 %, в бедренно-подколенном 80 % и 96 %, ниже колена 83 % и 84 %.
  3. 3.
    Pedal acceleration time as a diagnostic and prognostic tool in peripheral artery disease: systematic review and meta-analysis.
    BMC Med Imaging, 2026 · Мета-анализ · PMID 42426635
    Мета-анализ: время ускорения кровотока в артериях стопы выявляло значимую ишемию нижней конечности в сравнении с лодыжечно-плечевым индексом; удлинение было связано с риском незаживления ран и ампутации.
  4. 4.
    The utility of duplex scanning in infrainguinal vein graft surveillance: results from a randomised controlled study.
    Eur J Vasc Endovasc Surg, 1998 · РКИ · PMID 9715712
    РКИ на 179 пациентах: дополнительное дуплексное сканирование при наблюдении за венозными шунтами за год не улучшило первичную проходимость (74 % и 65 %).

Publications were found in PubMed; titles and journals are given verbatim, conclusions are a brief summary of the abstracts under the conditions of the specific studies. The level shows the volume of published data, not the value of the method: A — Plenty of data: consistent systematic reviews and meta-analyses of RCTs; B — Some data: reviews or several RCTs, results are heterogeneous; C — Little data: single RCTs or controlled studies; D — Scarce data: mainly reviews, observational and experimental studies. The passport is updated as new work is published and with regard to international practice.