Soft tissue ultrasound

Soft tissue ultrasound

Industry clinical and economic procedure passport. Full biological mechanism (MoA), patient preparation protocol, first-choice equipment fleet, integration into the resort's master treatment rooms and market price benchmarks.

Session duration
45 min
Turnover: ~60 min
Recommended course
10 sessions
однократно при первичном обращении; в исследованиях — при поступлении в отделение неотложной помощи — допущение для расчёта экономики; курс назначает врач
Throughput capacity
8 pts
per 8-hour shift
Median rate
2 000 ₽
1 450 ₽ – 2 600 ₽
Course cost
20 000 ₽
at market median
Publication volume
Level B
5 publ. in PubMed

Clinical profile

Ультразвуковое исследование кожи, подкожной клетчатки и мышц одной области: абсцесс или флегмона, поверхностные образования, инородные тела. Систематические обзоры и мета-анализы 2015–2022 годов оценили точность УЗИ при подозрении на абсцесс у взрослых и детей и при поиске инородных тел; отдельные работы описали дифференциацию поверхностных опухолей.

Каждое утверждение — со ссылкой на публикацию в списке ниже. Это срез опубликованных исследований, а не окончательная оценка метода: международная практика и интегральные протоколы часто опережают официальные публикации. Черновик по опубликованным исследованиям; требует проверки врачом. Редакция: 2026-10-31.

Mechanism of action

  • Абсцесс на УЗИ выглядит как отграниченное жидкостное скопление, что позволяет отличить его от диффузного воспаления клетчатки; в мета-анализе 8 исследований хорошего качества это различие отражено в высокой чувствительности метода. [1]

Where studies show an effect

  • Инфекции кожи и мягких тканей у взрослых: в мета-анализе 2017 года чувствительность УЗИ для абсцесса составила 96,2 %, специфичность 82,9 %. [1]
  • У детей в мета-анализе 2022 года чувствительность УЗИ для абсцесса составила 0,90 и специфичность 0,80, выше, чем при одном физикальном осмотре (0,84 и 0,69). [2]
  • Инородные тела мягких тканей: в мета-анализе 2015 года объединённая чувствительность 72 %, специфичность 92 %. [3]
  • Поверхностные опухоли мягких тканей: в серии из 247 образований чувствительность и специфичность УЗИ для злокачественных опухолей составили 94,1 % и 99,7 %. [4]

Open questions and study limitations

  • Исследования по инородным телам низкого качества и очень неоднородны (I² 90 %). [3]
  • В работе 2004 года точность УЗИ при диагностике липом с гистологической проверкой составила 49–64 % у разных исследователей при умеренном согласии между ними. [5]

Protocol in studies

  • В мета-анализе у детей (7 исследований, 870 пациентов) УЗИ выполняли в отделении неотложной помощи для разграничения абсцесса и воспаления клетчатки и сравнивали с физикальным осмотром. [2]
Contraindications. Область исследования и необходимость дополнительной визуализации или биопсии определяет врач. Не медицинская рекомендация: показания и противопоказания определяет врач.

Equipment fleet and fit-out

Certified first-choice medical equipment and compatible device systems

Equipment registry
Base configuration (Hero Device)
Ultrasound diagnostic system with vaginal probe

Device platform with proven validation of the biological response. Includes built-in biofeedback sensor systems, patient protection protocols and precision dosing of exposure.

Certification: Russian Ministry of Health registration certificate / CE Medical Device Directive Class IIa/IIb.
Compatible platforms in the MEDISPA.PRO registry
Logiq S8 medical ultrasound diagnostic system
Medical device, Roszdravnadzor registration certificate / CE
Device passport →

Architectural integration and treatment rooms

Resort rooms housing the treatment station (with SanPiN norms and MEP loads)

All treatment rooms →

Unit economics and resort price benchmarks

Market analysis based on a sample of premium sanatoriums, wellness hotels and preventive medicine clinics

Market price corridor
25th percentile (P25) 1 450 ₽
Market median 2 000 ₽
75th percentile (P75) 2 600 ₽

Median of prices in industry facilities' price lists, 2026

Basis of the price benchmark

Prices for this procedure appear in the price lists of 7 industry facilities; the median and interquartile range across facilities are shown (each facility counts once).

Procedure prices in the price directory →

Evidence base

The passport cites 5 publications verified in PubMed: systematic reviews and meta-analyses — 3, RCTs — 0, other clinical and observational studies — 0, reviews and other work — 2. The level shows how much data is published, not the value of the method.

Publication level B · Some data
  1. 1.
    In patients presenting to the emergency department with skin and soft tissue infections what is the diagnostic accuracy of point-of-care ultrasonography for the diagnosis of abscess compared to the current standard of care? A systematic review and meta-analysis.
    BMJ Open, 2017 · Мета-анализ · PMID 28073795
    Мета-анализ 8 исследований: при инфекциях кожи и мягких тканей УЗИ выявляло абсцесс с чувствительностью 96,2 % и специфичностью 82,9 %.
  2. 2.
    Role of point-of-care ultrasound (POCUS) in the diagnosis of an abscess in paediatric skin and soft tissue infections: a systematic review and meta-analysis.
    Med Ultrason, 2022 · Мета-анализ · PMID 34379709
    Мета-анализ у детей: чувствительность УЗИ для абсцесса 0,90, специфичность 0,80; у физикального осмотра — 0,84 и 0,69.
  3. 3.
    Diagnostic Accuracy of Ultrasonography in Retained Soft Tissue Foreign Bodies: A Systematic Review and Meta-analysis.
    Acad Emerg Med, 2015 · Мета-анализ · PMID 26111545
    Мета-анализ: УЗИ выявляло инородные тела мягких тканей с чувствительностью 72 % и специфичностью 92 % при низком качестве и высокой неоднородности исследований.
  4. 4.
    Ultrasound of musculoskeletal soft-tissue tumors superficial to the investing fascia.
    AJR Am J Roentgenol, 2014 · Исследование · PMID 24848846
    В серии из 247 поверхностных образований (96 % доброкачественные) чувствительность УЗИ для злокачественных опухолей 94,1 %, специфичность 99,7 %.
  5. 5.
    Soft-tissue lipomas: accuracy of sonography in diagnosis with pathologic correlation.
    Radiology, 2004 · Исследование · PMID 15486212
    При гистологической проверке точность УЗИ для липом составила 49–64 % у трёх исследователей, согласие между ними было умеренным.

Publications were found in PubMed; titles and journals are given verbatim, conclusions are a brief summary of the abstracts under the conditions of the specific studies. The level shows the volume of published data, not the value of the method: A — Plenty of data: consistent systematic reviews and meta-analyses of RCTs; B — Some data: reviews or several RCTs, results are heterogeneous; C — Little data: single RCTs or controlled studies; D — Scarce data: mainly reviews, observational and experimental studies. The passport is updated as new work is published and with regard to international practice.