MEDISPA.PRO
Ministry of Health code: A12.28.006 Ось M0 · Интегративная медицина 5P CEBM: Level B (Гинекология и урология)

Uroflowmetry

Uroflowmetry

Industry clinical and economic procedure passport. Full biological mechanism (MoA), patient preparation protocol, first-choice equipment fleet, integration into the resort's master treatment rooms and market price benchmarks.

Session duration
45 min
Turnover: ~60 min
Recommended course
1 sessions
Однократное измерение; при необходимости повторяют, в том числе с определением остаточной мочи; 1 процедур — допущение для расчёта экономики; курс назначает врач
Throughput capacity
8 pts
per 8-hour shift
Median rate
3 800 ₽
2 725 ₽ – 4 650 ₽
Course cost
3 800 ₽
at market median
Publication volume
Level B
8 publ. in PubMed

Clinical profile

Урофлоуметрия — неинвазивное измерение объёма и скорости потока мочи с построением кривой и определением максимальной и средней скорости. В систематическом обзоре неинвазивных тестов урофлоуметрия при пороге максимальной скорости ниже 10 мл/с дала медианную чувствительность 68% и специфичность 70% в выявлении инфравезикальной обструкции у мужчин; показатели зависят от объёма мочеиспускания, а диагноз обструкции уточняют инвазивным исследованием.

Каждое утверждение — со ссылкой на публикацию в списке ниже. Это срез опубликованных исследований, а не окончательная оценка метода: международная практика и интегральные протоколы часто опережают официальные публикации. Черновик по опубликованным исследованиям; требует проверки врачом. Редакция: 2026-10-29.

Mechanism of action

  • Измеряют объём и скорость потока за одно мочеиспускание; по кривой определяют максимальную и среднюю скорость, время достижения максимума и объём. [3]
  • Стандарт ICS задаёт практику, контроль качества, интерпретацию и отчётность уродинамических исследований, включая урофлоуметрию. [1]
  • Результат сопоставляют с объёмом мочеиспускания: в исследовании здоровых нерожавших женщин медиана максимальной скорости составила 29 мл/с при медиане объёма 241 мл. [3]

Where studies show an effect

  • Обследование мужчин с симптомами нижних мочевых путей: в обзоре 42 работ (4 444 пациента) урофлоуметрия при пороге ниже 10 мл/с имела медианную чувствительность 68% и специфичность 70% относительно инфузионно-перфузионного исследования. [2]
  • Прогнозирование обструкции по сочетанию неинвазивных тестов, включая урофлоуметрию: в проспективном многоцентровом исследовании 601 мужчины c-индекс модели составил 0,80 в разработке и 0,82 в валидации. [7]
  • Оценка выраженности препятствия при стриктуре уретры: максимальная скорость показала корреляцию средней силы с сохранностью просвета уретры. [8]

Open questions and study limitations

  • Показатели зависят от объёма мочеиспускания: кривые и скорости в группах с разным объёмом различались, а диапазон нормы у здоровых женщин оказался шире описанного ранее. [3]
  • Пороговые значения и определения обструкции различались между исследованиями, что ограничивает сопоставимость данных. [2]
  • Инвазивное уродинамическое исследование у здоровых добровольцев дало патологические находки у 71% (30/42), а повторяемость отдельных параметров была низкой, то есть норма по инвазивным данным определена неустойчиво. [6]
  • Инвазивное исследование остаётся ориентиром для диагноза обструкции: неинвазивные тесты ему уступают по точности и не заменяют его. [2]

Safety

  • Исследование неинвазивное: мочеиспускание происходит в урологический прибор; в использованных публикациях нежелательные явления не описаны. [1, 2]
  • Ограничение метода связано с условиями и объёмом: качество записи контролируют по стандарту ICS, а результат интерпретируют вместе с остаточной мочой. [1]

Protocol in studies

  • Измерение проводят при естественном позыве: объём мочеиспускания и максимальную скорость фиксирует прибор. [3]
  • Результат интерпретируют с учётом объёма мочеиспускания и остаточной мочи; требования к контролю качества задаёт стандарт ICS. [1]
  • Отдельное значение максимальной скорости не отделяет обструкцию от снижения сократимости, поэтому для уточнения применяют инвазивные исследования. [2]
Contraindications. Необходимость исследования и его объём определяет врач; при невозможности помочиться в прибор или при остром воспалении мочевых путей исследование переносят, текст носит информационный характер. Не медицинская рекомендация: показания и противопоказания определяет врач.

Equipment fleet and fit-out

Certified first-choice medical equipment and compatible device systems

Equipment registry
Base configuration (Hero Device)
Uroflowmeter with printer

Device platform with proven validation of the biological response. Includes built-in biofeedback sensor systems, patient protection protocols and precision dosing of exposure.

Certification: Russian Ministry of Health registration certificate / CE Medical Device Directive Class IIa/IIb.
Compatible platforms in the MEDISPA.PRO registry
Uroflowmeter with printer
Medical device, Roszdravnadzor registration certificate / CE
Device passport →

Architectural integration and treatment rooms

Resort rooms housing the treatment station (with SanPiN norms and MEP loads)

All treatment rooms →

Unit economics and resort price benchmarks

Market analysis based on a sample of premium sanatoriums, wellness hotels and preventive medicine clinics

Market price corridor
25th percentile (P25) 2 725 ₽
Market median 3 800 ₽
75th percentile (P75) 4 650 ₽

Median of prices in industry facilities' price lists, 2026

Basis of the price benchmark

Prices for this procedure appear in the price lists of 4 industry facilities; the median and interquartile range across facilities are shown (each facility counts once).

Procedure prices in the price directory →

Evidence base

The passport cites 8 publications verified in PubMed: systematic reviews and meta-analyses — 3, RCTs — 0, other clinical and observational studies — 1, reviews and other work — 4. The level shows how much data is published, not the value of the method.

Publication level B · Some data
  1. 1.
    International Continence Society Good Urodynamic Practices and Terms 2016: Urodynamics, uroflowmetry, cystometry, and pressure-flow study.
    Neurourol Urodyn, 2017 · Обзор · PMID 27917521
    Стандарт ICS 2016 уточнил более 30 терминов и задал требования к практике, контролю качества, интерпретации и отчётности уродинамики, включая урофлоуметрию.
  2. 2.
    Systematic Review of the Performance of Noninvasive Tests in Diagnosing Bladder Outlet Obstruction in Men with Lower Urinary Tract Symptoms.
    Eur Urol, 2017 · Систематический обзор · PMID 27687821
    Обзор 42 работ (4 444 пациента): урофлоуметрия при пороге максимальной скорости ниже 10 мл/с дала медианную чувствительность 68% и специфичность 70%; тест с манжетой, инфракрасная спектроскопия и толщина стенки детрузора показали более высокие оценки; инвазивное исследование остаётся ориентиром.
  3. 3.
    Evaluation of Uroflowmetry Curve Patterns and Nomogram Construct in Healthy Nulliparous Female Adults.
    Female Pelvic Med Reconstr Surg, 2022 · Исследование · PMID 34608033
    Проспективное исследование 164 здоровых нерожавших женщин: кривые и скорости зависят от объёма мочеиспускания, диапазон нормы шире описанного ранее.
  4. 4.
    Uroflowmetry in healthy women: A systematic review.
    Neurourol Urodyn, 2017 · Систематический обзор · PMID 27347839
    Систематический обзор: у здоровых женщин средняя максимальная скорость 23,5 мл/с, объём 338 мл, кривая нормальной формы у 70–80% мочеиспусканий; максимальная скорость зависела от объёма.
  5. 5.
    Comparative study of mobile acoustic uroflowmetry and conventional uroflowmetry: A systematic review and meta analysis.
    Neurourol Urodyn, 2024 · Мета-анализ · PMID 38369880
    Мета-анализ пяти исследований у мужчин: между мобильной акустической и обычной урофлоуметрией получены сильные и очень сильные положительные корреляции объёма, времени, средней и максимальной скорости.
  6. 6.
    Urodynamic Investigation: A Valid Tool to Define Normal Lower Urinary Tract Function?
    PLoS One, 2016 · Исследование · PMID 27736908
    Когортное исследование 42 здоровых добровольцев: инвазивное уродинамическое исследование выявило патологические находки у 71% (30/42), повторяемость отдельных параметров была низкой.
  7. 7.
    Diagnostic models for male lower urinary tract symptom management in primary care: a prospective, multicentre, diagnostic accuracy study.
    Br J Gen Pract, 2026 · Исследование · PMID 42242877
    Проспективное многоцентровое исследование 601 мужчины в 67 практиках: модель обструкции на основе простых тестов, включая урофлоуметрию, дала c-индекс 0,80 в разработке и 0,82 в независимой валидации.
  8. 8.
    Evaluation of non-invasive tests as diagnostic tools in assessment of bladder outlet obstruction severity in men with anterior urethral stricture.
    Cent European J Urol, 2021 · Исследование · PMID 34729232
    Исследование 63 мужчин со стриктурой уретры: показатели урофлоуметрии дали корреляцию средней силы с сохранностью просвета уретры, наиболее тесную связь показала максимальная скорость.

Publications were found in PubMed; titles and journals are given verbatim, conclusions are a brief summary of the abstracts under the conditions of the specific studies. The level shows the volume of published data, not the value of the method: A — Plenty of data: consistent systematic reviews and meta-analyses of RCTs; B — Some data: reviews or several RCTs, results are heterogeneous; C — Little data: single RCTs or controlled studies; D — Scarce data: mainly reviews, observational and experimental studies. The passport is updated as new work is published and with regard to international practice.